PH-117 6 in 1 Digital PH Meter Multi-Parameter Water Quality Tester Monitor
US $58.00-62.00 / piece
10 piece(s)Minimum order
warranty:
None
customized support:
OEM
place of origin:
Guangdong, China
brand name:
Generic
material:
ABS
color:
Black
Privacy Policy:
Samples are free within a certain price range
Other recommendations for your business
Contact us
Quik Detail
warranty | None |
---|---|
customized support | OEM |
place of origin | Guangdong, China |
brand name | Generic |
material | ABS |
color | Black |
Product name | PH-117 Digital PH Meter Multi-Parameter Water Quality Tester Monitor |
Type | Portable PH meter |
Model | PH-117 |
Material | ABS |
Weight | 0.23 KG |
Size | 15.2 x 8 x 2 CM |
Resolution | PH: 0.01PH |
Measurement range | PH: 0.00~14.00PH |
Accuracy | PH: ±0.1PH |
Working Temperature | 0℃~50℃ |
Product Detail
Products Description
PH-117 6 in 1 Digital PH Meter Multi-Parameter Water Quality Tester Monitor
Characteristics:
Widely used to measure the ORP / pH / RH / temperature / conductivity EC / CF / TDS(PPM) of solution/water.
Imported IC and high cost performance.
Test temperature in Centigrade/Fahrenheit (switchable unit).
Easy pH and TDS calibration with just a mini screwdriver.
You can monitor online for a long time.
It can work continuously more than 10 hours of power outage or outdoors without power after charging the battery for 3 hours.
FCC certified to offer safer and more accurate measurement.
Transparent LCD with backlight, 3 results displayed simultaneously.
Apply to water sources, aquariums, hydroponics, laboratory, spas, swimming pools and other water systems.
Automatic temperature compensation.
Easy to use and provides instant visualization of results.
Specifications:
Range: pH: 0.00 ~ 14.00pH
ORP: -1999mV ~ 1999mV
RH: 10% RH ~ 99% RH
Temperature: -50 Centigrade ~ 70 Centigrade (-58 Fahrenheit ~ 158 Fahrenheit)
EC: 0.00 ~ 19.99EC
CF : 0.0 ~ 199.9CF
TDS: 10 ~ 19990ppm
Resolution: pH: 0.01 pH
ORP: 1mV
RH: 1% RH
Temperature: 0.1 Centigrade (0.2 Fahrenheit)
EC: 0.01EC
CF: 0.1 CF
TDS: 10ppm
Accuracy: pH: ± 0.1 pH
ORP: ± 5mV
RH: 5% RH
Temperature: ± 1 centigrade (± 2 Fahrenheit)
CE, CF,TDS: ± 2% FS
Temperature compensation: 0 centigrade ~ 50 Centigrade (32 Fahrenheit ~ 122 Fahrenheit)
Working temperature: 0 centigrade ~ 50 centigrade (32 Fahrenheit ~ 122 Fahrenheit)
Power supply: DC 6V (power adapter usable)
Battery: 2 * NI-MH 4.8V battery (included)
Color: Black
Material: ABS
Type Plug: EU/US US (Optional)
Input Voltage: 100~240V
Item Size: 152*80*26mm/6.0*3.1*1.0in (Excluding Conductivity Probe)
Item Weight: 229g/8.1oz ( 7 body in 1 meter)
Package size: 23.5*16*6cm/9.3*6.3*2.4in
Package weight: 669.5g/23.6oz
Package list:
1 * 7 in 1 Water Quality Monitor with Conductivity Electrode
1 * User Manual
1 * pH Electrode
1 * ORP Electrode
1 * Temperature Electrode
1 * Adapter
2 * Suction Cups
1 * Holder
1 * Mini Screwdriver
Widely used to measure the ORP / pH / RH / temperature / conductivity EC / CF / TDS(PPM) of solution/water.
Imported IC and high cost performance.
Test temperature in Centigrade/Fahrenheit (switchable unit).
Easy pH and TDS calibration with just a mini screwdriver.
You can monitor online for a long time.
It can work continuously more than 10 hours of power outage or outdoors without power after charging the battery for 3 hours.
FCC certified to offer safer and more accurate measurement.
Transparent LCD with backlight, 3 results displayed simultaneously.
Apply to water sources, aquariums, hydroponics, laboratory, spas, swimming pools and other water systems.
Automatic temperature compensation.
Easy to use and provides instant visualization of results.
Specifications:
Range: pH: 0.00 ~ 14.00pH
ORP: -1999mV ~ 1999mV
RH: 10% RH ~ 99% RH
Temperature: -50 Centigrade ~ 70 Centigrade (-58 Fahrenheit ~ 158 Fahrenheit)
EC: 0.00 ~ 19.99EC
CF : 0.0 ~ 199.9CF
TDS: 10 ~ 19990ppm
Resolution: pH: 0.01 pH
ORP: 1mV
RH: 1% RH
Temperature: 0.1 Centigrade (0.2 Fahrenheit)
EC: 0.01EC
CF: 0.1 CF
TDS: 10ppm
Accuracy: pH: ± 0.1 pH
ORP: ± 5mV
RH: 5% RH
Temperature: ± 1 centigrade (± 2 Fahrenheit)
CE, CF,TDS: ± 2% FS
Temperature compensation: 0 centigrade ~ 50 Centigrade (32 Fahrenheit ~ 122 Fahrenheit)
Working temperature: 0 centigrade ~ 50 centigrade (32 Fahrenheit ~ 122 Fahrenheit)
Power supply: DC 6V (power adapter usable)
Battery: 2 * NI-MH 4.8V battery (included)
Color: Black
Material: ABS
Type Plug: EU/US US (Optional)
Input Voltage: 100~240V
Item Size: 152*80*26mm/6.0*3.1*1.0in (Excluding Conductivity Probe)
Item Weight: 229g/8.1oz ( 7 body in 1 meter)
Package size: 23.5*16*6cm/9.3*6.3*2.4in
Package weight: 669.5g/23.6oz
Package list:
1 * 7 in 1 Water Quality Monitor with Conductivity Electrode
1 * User Manual
1 * pH Electrode
1 * ORP Electrode
1 * Temperature Electrode
1 * Adapter
2 * Suction Cups
1 * Holder
1 * Mini Screwdriver






Operation:
1. Plug the power adapter into the power outlet.
2. Connect the pH or ORP electrode to the probe insert of the Instrument. Remove the protective cap.
3. Turn on the meter.
4. Immerse the electrode in the solution to be tested. Stir gently and wait for the reading to stabilize.
5. Press "/" key to switch between Celsius and Fahrenheit. Press "MODE" key to cycle through EC, CF OR TDS
measurements . 6. When you connect the ORP electrode, press the "MV" key. It will display the ORP value. 7. After use, turn off the meter. Rinse the electrode with tap water to minimize contamination. Replace the protective cap..
2. Connect the pH or ORP electrode to the probe insert of the Instrument. Remove the protective cap.
3. Turn on the meter.
4. Immerse the electrode in the solution to be tested. Stir gently and wait for the reading to stabilize.
5. Press "/" key to switch between Celsius and Fahrenheit. Press "MODE" key to cycle through EC, CF OR TDS
measurements . 6. When you connect the ORP electrode, press the "MV" key. It will display the ORP value. 7. After use, turn off the meter. Rinse the electrode with tap water to minimize contamination. Replace the protective cap..

PH calibration:
1. Pour a small amount of pH 6.86, pH 4.00 and pH 9.18 solution into clean beakers.
2. For particularly accurate calibration, it is recommended to use two beakers for each buffer solution: the first is used to
rinse the electrode, the second is used for calibration. In this WAV. The risks of contamination of the buffer solution are
reduced to a minimum.
3. Connect the power adapter. Turn on the meter.
4. Immerse the pH electrode in pH 6.86 buffer solution and shake it gently.
5. Allow the reading to stabilize using the supplied screwdriver. The "pH7" calibration screw reads "6.86" pH. Rinse the
electrode with tap water and suction with filter.
6. Immerse the pH electrode in the pH4.00 buffer solution and shake it gently.
7. Allow the reading to stabilize and using the supplied screwdriver, adjust the “pH4” calibration screw to read “4.00” pH. Rinse the electrode with tap water and suction with filter.
8. Immerse the pH electrode in the pH9.18 buffer solution until the display shows "9.18".
9. Calibration of the instrument's pH range is now complete.
Important:
The meter must be recalibrated in the following situations: * The meter has been used (placed) for a long time since the last calibration. * The meter has been used in particularly demanding conditions. * Maximum precision is required.
2. For particularly accurate calibration, it is recommended to use two beakers for each buffer solution: the first is used to
rinse the electrode, the second is used for calibration. In this WAV. The risks of contamination of the buffer solution are
reduced to a minimum.
3. Connect the power adapter. Turn on the meter.
4. Immerse the pH electrode in pH 6.86 buffer solution and shake it gently.
5. Allow the reading to stabilize using the supplied screwdriver. The "pH7" calibration screw reads "6.86" pH. Rinse the
electrode with tap water and suction with filter.
6. Immerse the pH electrode in the pH4.00 buffer solution and shake it gently.
7. Allow the reading to stabilize and using the supplied screwdriver, adjust the “pH4” calibration screw to read “4.00” pH. Rinse the electrode with tap water and suction with filter.
8. Immerse the pH electrode in the pH9.18 buffer solution until the display shows "9.18".
9. Calibration of the instrument's pH range is now complete.
Important:
The meter must be recalibrated in the following situations: * The meter has been used (placed) for a long time since the last calibration. * The meter has been used in particularly demanding conditions. * Maximum precision is required.

EC CF ppm calibration:
1. Press the "MODE" key. Select "EC." Immerse the EC electrode in a 12880 ms/cm (12.88 EC) calibration solution.
2. Allow the reading to stabilize and using a small screwdriver turn the
CAL Calibration Trimmer until the display shows "12.88EC". Rinse the
Electrode with distilled water and dry with filter paper.
3. Immerse the EC electrode in 1413 US/cm (1.41EC) calibration solution until the screen shows "1413 (1.41EC)"
Notice:
1. Gently shake the meter when using it. Do not let anything form on the electrode.
2. In case of abnormal phenomena such as high measured deviation, flashing measured value, no reset to zero, etc., please immerse the electrode in alcohol to clean it.
3. If the protective cap has been out of electrolyte, or if the electrode has not been used for a long time, the electrode should be reactivated by leaving it for several hours in a beaker containing normal tap water.
4. When the power adapter is n ot used, if the meter cannot be turned on or the screen fades out. Plug the power adapter into thepower outlet. It will charge the rechargeable battery. And it works too.
2. Allow the reading to stabilize and using a small screwdriver turn the
CAL Calibration Trimmer until the display shows "12.88EC". Rinse the
Electrode with distilled water and dry with filter paper.
3. Immerse the EC electrode in 1413 US/cm (1.41EC) calibration solution until the screen shows "1413 (1.41EC)"
Notice:
1. Gently shake the meter when using it. Do not let anything form on the electrode.
2. In case of abnormal phenomena such as high measured deviation, flashing measured value, no reset to zero, etc., please immerse the electrode in alcohol to clean it.
3. If the protective cap has been out of electrolyte, or if the electrode has not been used for a long time, the electrode should be reactivated by leaving it for several hours in a beaker containing normal tap water.
4. When the power adapter is n ot used, if the meter cannot be turned on or the screen fades out. Plug the power adapter into thepower outlet. It will charge the rechargeable battery. And it works too.



Related Products
Company Profile



Packaging & Delivery